双队列的打通 实时按钮的切换 补充测试用例
This commit is contained in:
@@ -0,0 +1,216 @@
|
||||
using System;
|
||||
using System.Threading;
|
||||
using System.Windows.Media;
|
||||
using System.Windows.Media.Imaging;
|
||||
using System.Windows.Threading;
|
||||
using FsCheck;
|
||||
using FsCheck.Fluent;
|
||||
using FsCheck.Xunit;
|
||||
using Moq;
|
||||
using Prism.Events;
|
||||
using XP.Common.Logging.Interfaces;
|
||||
using XplorePlane.Events;
|
||||
using XplorePlane.Models;
|
||||
using XplorePlane.Services.AppState;
|
||||
using XplorePlane.Services.MainViewport;
|
||||
using XplorePlane.ViewModels;
|
||||
|
||||
namespace XplorePlane.Tests.ViewModels
|
||||
{
|
||||
/// <summary>
|
||||
/// FsCheck property-based tests for ViewportPanelViewModel.
|
||||
/// Properties 9–10 validate IsAnimatedSwitchEnabled logic and ImageInfo protection.
|
||||
/// </summary>
|
||||
public class ViewportPanelViewModelPropertyTests
|
||||
{
|
||||
// ── Helpers ──────────────────────────────────────────────────────────
|
||||
|
||||
/// <summary>
|
||||
/// Runs an action on a dedicated STA thread with a SynchronizationContext,
|
||||
/// which satisfies Prism's UIThread requirement for EventAggregator.
|
||||
/// </summary>
|
||||
private static T RunOnStaThread<T>(Func<T> action)
|
||||
{
|
||||
T result = default;
|
||||
Exception exception = null;
|
||||
|
||||
var thread = new Thread(() =>
|
||||
{
|
||||
SynchronizationContext.SetSynchronizationContext(new DispatcherSynchronizationContext());
|
||||
try
|
||||
{
|
||||
result = action();
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
exception = ex;
|
||||
}
|
||||
});
|
||||
thread.SetApartmentState(ApartmentState.STA);
|
||||
thread.Start();
|
||||
thread.Join();
|
||||
|
||||
if (exception != null)
|
||||
throw new Exception("STA thread threw an exception", exception);
|
||||
|
||||
return result;
|
||||
}
|
||||
|
||||
// ── Property 9 ───────────────────────────────────────────────────────
|
||||
|
||||
// Feature: live-image-display, Property 9: AnimatedSwitch 可用状态与连接/CNC 状态一致
|
||||
// Validates: Requirements 3.13, 7.5, 7.6
|
||||
//
|
||||
// For any combination of IsDetectorConnected and IsCncRunning,
|
||||
// IsAnimatedSwitchEnabled always equals IsDetectorConnected && !IsCncRunning.
|
||||
//
|
||||
// The implementation in ViewportPanelViewModel computes:
|
||||
// IsAnimatedSwitchEnabled = _isDetectorConnected && !_isCncRunning
|
||||
// We verify this formula holds for all boolean combinations.
|
||||
[Property(MaxTest = 100)]
|
||||
public Property IsAnimatedSwitchEnabled_AlwaysEqualsDetectorConnectedAndNotCncRunning()
|
||||
{
|
||||
var gen =
|
||||
from isDetectorConnected in ArbMap.Default.GeneratorFor<bool>()
|
||||
from isCncRunning in ArbMap.Default.GeneratorFor<bool>()
|
||||
select (isDetectorConnected, isCncRunning);
|
||||
|
||||
return Prop.ForAll(
|
||||
gen.ToArbitrary(),
|
||||
tuple =>
|
||||
{
|
||||
var (isDetectorConnected, isCncRunning) = tuple;
|
||||
|
||||
// Run the entire test on a single STA thread with SynchronizationContext
|
||||
return RunOnStaThread(() =>
|
||||
{
|
||||
var mockViewport = new Mock<IMainViewportService>();
|
||||
mockViewport.Setup(s => s.CurrentDisplayImage).Returns((ImageSource)null);
|
||||
mockViewport.Setup(s => s.CurrentDisplayInfo).Returns("等待探测器图像...");
|
||||
mockViewport.Setup(s => s.IsRealtimeDisplayEnabled).Returns(true);
|
||||
mockViewport.Setup(s => s.IsCncRunning).Returns(isCncRunning);
|
||||
|
||||
var mockAppState = new Mock<IAppStateService>();
|
||||
mockAppState.SetupAdd(s => s.DetectorStateChanged += It.IsAny<EventHandler<StateChangedEventArgs<DetectorState>>>());
|
||||
|
||||
var mockLogger = new Mock<ILoggerService>();
|
||||
mockLogger.Setup(l => l.ForModule<ViewportPanelViewModel>()).Returns(mockLogger.Object);
|
||||
|
||||
var eventAggregator = new EventAggregator();
|
||||
|
||||
var vm = new ViewportPanelViewModel(
|
||||
mockViewport.Object,
|
||||
eventAggregator,
|
||||
mockAppState.Object,
|
||||
mockLogger.Object);
|
||||
|
||||
// Simulate detector connection state change via DetectorStateChanged event.
|
||||
var detectorState = new DetectorState(isDetectorConnected, false, 0, "");
|
||||
var oldState = new DetectorState(!isDetectorConnected, false, 0, "");
|
||||
var stateChangedArgs = new StateChangedEventArgs<DetectorState>(oldState, detectorState);
|
||||
mockAppState.Raise(s => s.DetectorStateChanged += null, stateChangedArgs);
|
||||
|
||||
// Pump the dispatcher to process BeginInvoke callbacks
|
||||
Dispatcher.CurrentDispatcher.Invoke(() => { }, DispatcherPriority.Background);
|
||||
|
||||
// Simulate CNC running state via StateChanged on the viewport service
|
||||
mockViewport.Setup(s => s.IsCncRunning).Returns(isCncRunning);
|
||||
mockViewport.Raise(s => s.StateChanged += null, EventArgs.Empty);
|
||||
|
||||
// Pump the dispatcher again
|
||||
Dispatcher.CurrentDispatcher.Invoke(() => { }, DispatcherPriority.Background);
|
||||
|
||||
// The core invariant: IsAnimatedSwitchEnabled == IsDetectorConnected && !IsCncRunning
|
||||
return vm.IsAnimatedSwitchEnabled == (vm.IsDetectorConnected && !isCncRunning);
|
||||
});
|
||||
});
|
||||
}
|
||||
|
||||
// ── Property 10 ──────────────────────────────────────────────────────
|
||||
|
||||
// Feature: live-image-display, Property 10: 测量模式下 ImageInfo 不被覆盖
|
||||
// Validates: Requirements 5.3
|
||||
//
|
||||
// For any active measurement mode (CurrentMeasurementMode != None) and any number
|
||||
// of StateChanged triggers, ImageInfo always retains the measurement hint text
|
||||
// and is not overwritten by service state.
|
||||
//
|
||||
// Implementation note: ViewportPanelViewModel.OnMainViewportStateChanged calls
|
||||
// UpdateFromState(updateInfo: CurrentMeasurementMode == MeasurementToolMode.None)
|
||||
// When CurrentMeasurementMode != None, updateInfo is false, so ImageInfo is NOT updated.
|
||||
// We verify this by directly setting CurrentMeasurementMode and triggering StateChanged.
|
||||
[Property(MaxTest = 100)]
|
||||
public Property ActiveMeasurementMode_ImageInfo_NotOverwrittenByStateChanged()
|
||||
{
|
||||
// Generate non-None measurement modes
|
||||
var modeGen = Gen.Elements(
|
||||
MeasurementToolMode.PointDistance,
|
||||
MeasurementToolMode.PointLineDistance,
|
||||
MeasurementToolMode.Angle,
|
||||
MeasurementToolMode.ThroughHoleFillRate);
|
||||
|
||||
var gen =
|
||||
from mode in modeGen
|
||||
from triggerCount in Gen.Choose(1, 20)
|
||||
select (mode, triggerCount);
|
||||
|
||||
return Prop.ForAll(
|
||||
gen.ToArbitrary(),
|
||||
tuple =>
|
||||
{
|
||||
var (mode, triggerCount) = tuple;
|
||||
|
||||
// Run the entire test on a single STA thread with SynchronizationContext
|
||||
return RunOnStaThread(() =>
|
||||
{
|
||||
var mockViewport = new Mock<IMainViewportService>();
|
||||
mockViewport.Setup(s => s.CurrentDisplayImage).Returns((ImageSource)null);
|
||||
mockViewport.Setup(s => s.CurrentDisplayInfo).Returns("等待探测器图像...");
|
||||
mockViewport.Setup(s => s.IsRealtimeDisplayEnabled).Returns(true);
|
||||
mockViewport.Setup(s => s.IsCncRunning).Returns(false);
|
||||
|
||||
var mockAppState = new Mock<IAppStateService>();
|
||||
mockAppState.SetupAdd(s => s.DetectorStateChanged += It.IsAny<EventHandler<StateChangedEventArgs<DetectorState>>>());
|
||||
|
||||
var mockLogger = new Mock<ILoggerService>();
|
||||
mockLogger.Setup(l => l.ForModule<ViewportPanelViewModel>()).Returns(mockLogger.Object);
|
||||
|
||||
var eventAggregator = new EventAggregator();
|
||||
|
||||
var vm = new ViewportPanelViewModel(
|
||||
mockViewport.Object,
|
||||
eventAggregator,
|
||||
mockAppState.Object,
|
||||
mockLogger.Object);
|
||||
|
||||
// Directly set the measurement mode on the ViewModel.
|
||||
// This bypasses the UIThread event dispatch issue and directly
|
||||
// sets the backing field that controls ImageInfo protection.
|
||||
vm.CurrentMeasurementMode = mode;
|
||||
|
||||
// Set ImageInfo to the measurement hint text (as OnMeasurementToolActivated would)
|
||||
vm.ImageInfo = vm.MeasurementModeText;
|
||||
string measurementInfo = vm.ImageInfo;
|
||||
|
||||
// Verify measurement mode is active
|
||||
if (vm.CurrentMeasurementMode == MeasurementToolMode.None)
|
||||
return false;
|
||||
|
||||
// Trigger StateChanged multiple times.
|
||||
// The handler calls BeginInvoke — we pump the dispatcher to process callbacks.
|
||||
for (int i = 0; i < triggerCount; i++)
|
||||
{
|
||||
mockViewport.Raise(s => s.StateChanged += null, EventArgs.Empty);
|
||||
// Pump the dispatcher to process BeginInvoke callbacks
|
||||
Dispatcher.CurrentDispatcher.Invoke(() => { }, DispatcherPriority.Background);
|
||||
}
|
||||
|
||||
// ImageInfo must still be the measurement hint text, not the service info.
|
||||
// This holds because UpdateFromState is called with updateInfo: false
|
||||
// when CurrentMeasurementMode != None.
|
||||
return vm.ImageInfo == measurementInfo;
|
||||
});
|
||||
});
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user