using System;
|
||
|
||
namespace XP.Hardware.RaySource.Config
|
||
{
|
||
/// <summary>
|
||
/// 射线源配置实体类 | X-Ray Source Configuration Entity
|
||
/// 包含PVI通讯参数、硬件参数和操作超时配置 | Contains PVI communication parameters, hardware parameters, and operation timeout configuration
|
||
/// </summary>
|
||
public class RaySourceConfig
|
||
{
|
||
#region PVI通讯参数 | PVI Communication Parameters
|
||
|
||
/// <summary>
|
||
/// 射线源类型 | Ray source type
|
||
/// 可选值: Comet225 | Available values: Comet225
|
||
/// </summary>
|
||
public string SourceType { get; set; } = "Comet225";
|
||
|
||
/// <summary>
|
||
/// PLC IP地址 | PLC IP Address
|
||
/// </summary>
|
||
public string PlcIpAddress { get; set; } = "192.168.12.10";
|
||
|
||
/// <summary>
|
||
/// PLC端口号 | PLC Port Number
|
||
/// </summary>
|
||
public int PlcPort { get; set; } = 11159;
|
||
|
||
/// <summary>
|
||
/// 源站号 | Source Station Number
|
||
/// </summary>
|
||
public int StationNumber { get; set; } = 1;
|
||
|
||
/// <summary>
|
||
/// 源端口号 | Source Port Number
|
||
/// </summary>
|
||
public int PortNumber { get; set; } = 11;
|
||
|
||
/// <summary>
|
||
/// CPU名称 | CPU Name
|
||
/// </summary>
|
||
public string CpuName { get; set; } = "cpu";
|
||
|
||
/// <summary>
|
||
/// 连接超时时间(毫秒)| Connection timeout (milliseconds)
|
||
/// </summary>
|
||
public int ConnectionTimeout { get; set; } = 5000;
|
||
|
||
#endregion
|
||
|
||
#region 硬件参数范围 | Hardware Parameter Ranges
|
||
|
||
/// <summary>
|
||
/// 最小电压(kV)| Minimum voltage (kV)
|
||
/// </summary>
|
||
public float MinVoltage { get; set; } = 20f;
|
||
|
||
/// <summary>
|
||
/// 最大电压(kV)| Maximum voltage (kV)
|
||
/// </summary>
|
||
public float MaxVoltage { get; set; } = 225f;
|
||
|
||
/// <summary>
|
||
/// 最小电流(μA)| Minimum current (μA)
|
||
/// </summary>
|
||
public float MinCurrent { get; set; } = 10f;
|
||
|
||
/// <summary>
|
||
/// 最大电流(μA)| Maximum current (μA)
|
||
/// </summary>
|
||
public float MaxCurrent { get; set; } = 1000f;
|
||
|
||
#endregion
|
||
|
||
#region 外部程序配置 | External Program Configuration
|
||
|
||
/// <summary>
|
||
/// 高级设置外部程序路径 | Advance settings external program path
|
||
/// </summary>
|
||
public string AdvanceExePath { get; set; } = @"C:\Program Files (x86)\Feinfocus\FXEControl_3.1.1.65\FXEControl.exe";
|
||
|
||
/// <summary>
|
||
/// Host 进程可执行文件路径(可选)
|
||
/// 为空时默认在主程序输出目录下查找 XP.Hardware.RaySource.Comet.Host.exe
|
||
/// </summary>
|
||
public string HostExePath { get; set; }
|
||
|
||
#endregion
|
||
|
||
#region 操作超时配置 | Operation Timeout Configuration
|
||
|
||
/// <summary>
|
||
/// 初始化超时时间(毫秒)| Initialization timeout (milliseconds)
|
||
/// </summary>
|
||
public int InitializationTimeout { get; set; } = 30000;
|
||
|
||
/// <summary>
|
||
/// 暖机超时时间(毫秒)| Warm-up timeout (milliseconds)
|
||
/// </summary>
|
||
public int WarmUpTimeout { get; set; } = 300000; // 5分钟
|
||
|
||
/// <summary>
|
||
/// 启动超时时间(毫秒)| Startup timeout (milliseconds)
|
||
/// </summary>
|
||
public int StartUpTimeout { get; set; } = 180000; // 3分钟
|
||
|
||
/// <summary>
|
||
/// 自动定心超时时间(毫秒)| Auto-center timeout (milliseconds)
|
||
/// </summary>
|
||
public int AutoCenterTimeout { get; set; } = 120000; // 2分钟
|
||
|
||
/// <summary>
|
||
/// 灯丝调整超时时间(毫秒)| Filament adjust timeout (milliseconds)
|
||
/// </summary>
|
||
public int FilamentAdjustTimeout { get; set; } = 120000; // 2分钟
|
||
|
||
/// <summary>
|
||
/// 一般操作超时时间(毫秒)| General operation timeout (milliseconds)
|
||
/// </summary>
|
||
public int GeneralOperationTimeout { get; set; } = 10000;
|
||
|
||
#endregion
|
||
|
||
#region 灯丝寿命配置 | Filament Lifetime Configuration
|
||
|
||
/// <summary>
|
||
/// 射线源序列号 | Ray source serial number
|
||
/// 用于唯一标识设备,灯丝寿命管理依赖此字段匹配设备记录
|
||
/// Used to uniquely identify the device, filament lifetime management relies on this field to match device records
|
||
/// </summary>
|
||
public string SerialNumber { get; set; } = "";
|
||
|
||
/// <summary>
|
||
/// 灯丝总寿命阈值(小时)| Filament total lifetime threshold (hours)
|
||
/// 默认值为 1000 小时,超过阈值时系统将发出预警
|
||
/// Default value is 1000 hours, system will issue a warning when threshold is exceeded
|
||
/// </summary>
|
||
public int TotalLifeThreshold { get; set; } = 1000;
|
||
|
||
#endregion
|
||
|
||
/// <summary>
|
||
/// 验证配置参数有效性 | Validate configuration parameters
|
||
/// </summary>
|
||
/// <returns>验证结果 | Validation result</returns>
|
||
public (bool IsValid, string ErrorMessage) Validate()
|
||
{
|
||
if (string.IsNullOrWhiteSpace(PlcIpAddress))
|
||
return (false, "PLC IP地址不能为空");
|
||
|
||
if (PlcPort <= 0 || PlcPort > 65535)
|
||
return (false, "PLC端口号必须在1-65535之间");
|
||
|
||
if (MinVoltage >= MaxVoltage)
|
||
return (false, "最小电压必须小于最大电压");
|
||
|
||
if (MinCurrent >= MaxCurrent)
|
||
return (false, "最小电流必须小于最大电流");
|
||
|
||
if (ConnectionTimeout <= 0)
|
||
return (false, "连接超时时间必须大于0");
|
||
|
||
return (true, null);
|
||
}
|
||
}
|
||
}
|